When specifying a helical compression spring for a medical device, start with two separate questions: will it fit the assembly, and will it deliver the required force at its working positions?
A spring can meet its dimensional limits yet produce an unsuitable mechanical response. Equally, meeting a force requirement does not confirm that it will fit its housing or locate correctly.
Distinguishing these requirements helps design and procurement teams communicate priorities, assess competing constraints and agree appropriate acceptance checks. The principles below concern helical compression springs; suitability for a particular medical application still requires application-specific assessment and verification.
Dimensional requirements define the spring’s physical geometry. Important dimensions include wire diameter, outside or inside diameter, and free length. End configuration and solid height—the length when the coils are fully compressed together—also affect installation and available travel.
Wire diameter is the thickness of the wire forming the coil. Outside diameter is measured across the coil’s outer surfaces; inside diameter describes the opening through its centre. Mean coil diameter follows the centreline of the wire. For round wire:
Mean coil diameter = (outside diameter + inside diameter) / 2
A drawing should identify which diameter is specified rather than using the ambiguous term “spring diameter”.

Figure 1. Wire diameter, outside diameter, inside diameter, mean coil diameter and free length, with solid height shown separately.
Free length is the spring’s overall length without an external compressive load. It provides a reference for calculating deflection but does not, by itself, establish the installed force.
The outside diameter must allow suitable clearance within a housing, while the inside diameter may need to accommodate a guide rod. Assess clearance against dimensional tolerances and changes during compression, not just nominal unloaded dimensions.
A force requirement needs a defined working position. This can be a specified compressed length or a stated deflection from free length. “Required force” alone does not provide enough information to assess a spring.
Spring force and spring rate are different quantities. For a spring behaving linearly over the relevant working range, rate describes the change in force per unit of deflection, commonly expressed in newtons per millimetre (N/mm):
Change in force = spring rate × change in deflection
An installed spring may already be compressed before the mechanism begins its operating movement. This initial compression creates preload.

Figure 2. Initial compression creates preload; further deflection increases force within the illustrated linear working range.
Spring rate depends on wire diameter, mean coil diameter, the number of active coils and the material’s shear modulus. Specifying a material or wire size alone therefore does not establish the spring’s response.
Where behaviour is nonlinear, one rate may not adequately describe the full movement. Specify forces at important working positions or agree an appropriate force–deflection requirement.
A dimensional tolerance defines the permitted variation in a physical feature. A force tolerance defines the permitted variation in load at a stated position.
A spring may satisfy its free-length tolerance but fall outside the required force limits at its installed length. Conversely, meeting a force requirement does not establish that the spring will clear its housing or sit correctly on its seating surfaces.
State the target force or permitted force range, the corresponding compressed length or deflection, and relevant test conditions. Distinguish between testing at a fixed overall length and testing at a deflection measured from each spring’s actual free length.
Avoid applying tight tolerances to every feature without considering function. Identify which dimensions control fit and which force points control performance, then assess whether the combined requirements are achievable.
Dimensional inspection checks physical features against specified limits. Force testing checks mechanical response at defined positions under agreed conditions. Passing one check does not establish compliance with the other.

Figure 3. Measuring spring geometry and measuring load at a defined compressed length verify different requirements.
Acceptance requirements should identify the checks, measurement references and any relevant loading or conditioning procedures. Where performance depends on repeated cycling or environmental exposure, initial dimensional and force checks alone cannot establish performance throughout service life.
Available travel also needs consideration. Maximum working compression should leave appropriate clearance from solid height and remain within the design’s permitted stress limits. Neither free length nor spring rate alone establishes safe working travel.

Figure 4. Working travel ends before solid height, with clearance shown separately; permitted stress may impose an earlier operating limit.
Discuss the requirements before finalising the drawing if installation space, travel and force targets compete, or if material choice and operating conditions remain unresolved. This allows manufacturing feasibility and specification priorities to be considered together.
European Springs Ireland’s compression springs information describes both standard options and support for developing a custom spring from an application brief.
For a useful enquiry, provide:
Mark unresolved information as provisional and explain which requirements take priority. If no drawing is available, describe the application and the information already known rather than treating assumptions as final specifications.
For medical-device projects, component inspection alone does not establish suitability for a particular medical use. Material compatibility, biocompatibility where applicable, cleaning or sterilisation exposure, and device-level verification and validation remain separate considerations.
To start an enquiry, submit your spring requirements and any available technical drawings to European Springs Ireland.